Episode 82 ~2:10 MV Switchgear EN · العربية

Zhaga, swappable LED sockets

Zhaga is an industry consortium publishing 'books' that standardise LED modules, drivers, sockets, and sensors. Book 18 = outdoor LED engine. Book 20 = NEMA 7-pin equivalent for street lights. Book 24 = sensor add-on socket. Buying Zhaga-compliant fixtures means you can swap LED engines or sensors years later without changing the housing.

Animated explainer, press play to watch the concepts now; the filmed cut publishes once production wraps.

What you'll walk away with

Four ideas to carry into the next specification conversation you have.

01

Zhaga = open LED-module standard.

Defines socket geometry, electrical interface, thermal spec. Open consortium, not single vendor.

02

Book 18, outdoor LED engine.

Replaceable LED+driver module for streetlights, floodlights. Upgrade efficacy without re-poling.

03

Book 20, NEMA 7-pin equivalent.

DALI-2 + DALI bus + auxiliary power. Used for street smart-city controllers (Saudi smart cities mandate it).

04

Book 24, sensor add-on.

Mount IR / radar / camera modules to existing luminaire via standardised socket. Add features later.

Zhaga books × scope

Which Zhaga book covers which standardisation.

Book Scope Use
Book 3Square indoor LED engineOffice downlights
Book 7Round LED engine + driverSpots
Book 11Linear LED engineOffice linears
Book 18Outdoor LED+driver moduleStreetlights
Book 20Smart-city receptacleDALI-2 controllers
Book 24Sensor add-onSmart sensors

Why Zhaga matters now

Five reasons Saudi smart-city LED projects mandate Zhaga.

Future-proof without re-poling.

LED efficacy improved 50% from 2015 to 2025. Zhaga lets cities swap engines on existing poles, saving the cost of pole replacement.

Smart-city sensor retrofit.

NEOM and Riyadh smart-light projects require sensor sockets. Book 24 means cameras, environmental sensors, 5G small-cells can be added later.

Multi-vendor competition.

Zhaga compliance means cities aren't locked to one LED supplier. Saudi muni RFPs increasingly require Zhaga as a precondition for bid.

Warranty-friendly maintenance.

Cities don't have to throw away the whole fixture when a driver fails. Replace just the Zhaga module, drops 5-year TCO significantly.

EN 60598-1 + Zhaga = certified safe.

Zhaga doesn't replace electrical safety standards. It complements them, the LED module is still tested per EN 60598, but the socket is universal.