Industrial & warehouse, 200-1000 lux at height

Industrial spaces are tough: high mounting (8-15 m), dust, vibration, sometimes humidity or chemicals. EN 12464-1 sets lux by task (aisles 100, packing 300, fine assembly 1000+) and demands the fixture survive the environment, IP65, IK08+ minimum. Modern facilities cut energy 60% with LED high-bays plus motion sensing on infrequently-used aisles.

Animated explainer, press play to watch the concepts now; the filmed cut publishes once production wraps.

What you'll walk away with

Four ideas to carry into the next specification conversation you have.

01

Lux by task, not by area.

Aisle walking 100 lux. Packing zone 300 lux. Inspection bench 1000 lux. Each task gets its own design.

02

IP65 + IK08 minimum.

Dust, hose-down, forklift bumps. Fixtures must survive. Below IP54 = early failures.

03

Mounting heights drive lumen needs.

Same 100 lux at floor needs different lumen output at 6 m, 9 m, 12 m. Photometric calculation is essential.

04

Motion sensors save 30-60% energy.

Warehouse aisles are empty 80% of the day. Smart bay-level sensors dim to 10% when empty, full when forklift enters.

Industrial zones, EN 12464-1 + IP

Lux, IP rating, and IK impact rating by industrial application.

Space Lux IP / IK
Warehouse aisle100-150IP54 / IK07
Packing area300IP65 / IK08
Loading dock150 + 50 outdoorIP65 / IK08
General assembly300-500IP54 / IK07
Fine assembly / inspection750-1000IP54 / IK07
Quality control1000 + 1500 taskIP54 / IK07
Cold storage100-200IP65 / IK10
Outdoor yard20-50IP66 / IK10

Industrial lighting done right

Five decisions that separate compliant from excellent.

High-bay LED replaced metal halide everywhere.

150W LED replacing 400W HID. Same lux, 60% less energy, 3× the life, no warm-up, full dimming. Payback under 18 months.

Motion + daylight sensing is now standard.

DALI-2 with motion + ambient sensors per bay. Empty aisle dims to 10%. Skylight on bright day kills electric. Saudi warehouses report 40-55% energy savings.

Glare control even in warehouses.

Forklift operators looking up = direct view of fixtures. Linear UGR-controlled high-bays or louvres prevent operator fatigue.

Emergency lighting for safe egress.

EN 1838 requires 1 lux on escape routes within 5 seconds of failure. Self-contained or CBS feeding emergency-rated fixtures.

Vibration-rated drivers in heavy duty.

Forging, stamping, machine shops produce constant vibration. Standard drivers fail in 6-12 months. Specify vibration-rated (IEC 60068-2-6).